Hampton Controls, Inc.
Phone (724) 861 0150 Fax (724) 861-0160
Email sales@hamptoncontrols.com
Home Page MOTOR DRIVES Controls Division
Vari Speed S1000 Cycletrol Series MOC-1 Bi-Directional Vari Speed 180 Series
|
||||||||||||||||||||||||||||||||||||||
Vari Speed® S1000 |
||||||||||||||||||||||||||||||||||||||
|
The Vari Speed® S1000 is a high-performance DC motor speed control designed for maximum reliability in 1/20 to 2 HP applications. The surface mount technology incorporated into the design reduces package size and improves reliability... creating a savings in both cost and space for you. Options
|
||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||
| Control
Specifications Service factor: 1.0 Duty: continuous Overload Capability: 150% for one minute Speed Regulation: • ±2% of base speed (for 95% load change) • ±1% of base speed due to line voltage fluctuation Speed Range: 50:1 at full torque Speed Input: • 5K ohm potentiometer 1 watt • 0-5 or 0-10 VDC process signal, (must be isolated) Adjustments: • Minimum speed (0-50% motor base speed) • Maximum speed (50-110% motor base speed) • Current (torque) limit (10-150% control rating) • IR compensation (0-25% rated output) • Acceleration (0.5-15 sec.) • Deceleration (0.5-15 sec.) AC Line Voltage Variation: Rated voltage (±10%) AC Line Frequency: 48 to 62 Hz Ambient Temperature: 32°F to 131°F; (0°C to 55°C) Elevation: Up to 3,300 ft. with derating | ||||||||||||||||||||||||||||||||||||||
|
SELECTION
* External Heatsink: P/N(176B1122) or equivalent required Pump Control Options Available |
||||||||||||||||||||||||||||||||||||||
|
S1000 Dimensions |
||||||||||||||||||||||||||||||||||||||
| Vari Speed S1000 Cycletrol Series MOC-1 Bi-Directional Vari Speed 180 Series | ||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||